Learn What A Type J Thermocouple Is Used For

By Claudette Lambert


There are several kinds of thermocouples available on the market today; these are all distinguished by means of charts and color coding. However there are four common calibrations, namely; K, J, E and T. Each one of these calibrations has a specific temperature range suited to their requirements and usage. The type J thermocouple is specifically used for any legacy temperature recordings and mainly found on control equipment.

The J-thermocouple is able to be modified to fit either small or standard type connections. They can be employed in readings such as gas and air exposure as well as fluid immersion. Plus they can also be adapted to do readings in malleable solid permeation, together with air and outer surface temperature levels.

Characteristically J-models are fabricated from the use of copper-nickel alloy and iron; their wires are set out with the negative one being copper-nickel alloys while the positive one is the iron wire. Although they are not as popular as some other thermocouples they are plentiful and a lot cheaper to purchase. The reason they are not used as often is due to their increased risk of rust and the fact that their temperature scope is relatively low; between -40 and 750 Celsius.

When it comes to the actual wiring of these couplers, it is vital that the correct wires are spliced together that match the specific type of coupler and its use. Because these wires are polarity receptive it may cause severe complications is one mixes for instance J and K type wires. Even though both of these couplers have a red negative wire, one must always remember to join like colored wires together.

Careful attention should also be paid to any outside sources of errors that will possibly impact their overall measurements or reading accuracy. Output signals are in milli- volt measurements and generally one will find they have small voltage to temperature sensitivity. Therefore the foremost sources of error for defined measurements to allow for are thermocouple malfunctions, noise errors and gain errors, accuracy balance as well as cold-junction return.

Two special metals are welded to each other to create these small temperature gauges; the difference in temperature at the point of connection generates electromotive forces. The basic theory behind any thermocouple instrumentation is the thermoelectric effects which are known in the industry as a Seebeck effect. This is still extensively used today as a very popular technique to measure temperature.

In order to eliminate possible errors the manufacturers have a configuration guide that will ensure that all components are used for the correct application. Furthermore, they also offer technical support from expert engineers for any clients. Guidelines seem to be similar but there may be slight differences between manufacturers.

Thermocouples need specific control programs that suit all requirements to obtain truthful readings. Thermocouple compositions can be re-calibrated due to magnetic sways or exposure to excessive heat. It is in these instances that the type j thermocouple is not designed for temperatures above 760 degrees.